Selaa lähdekoodia

Fix some THERMAL_PROTECTION_CHAMBER issues (#13678)

Stephan 5 vuotta sitten
vanhempi
commit
483822f3aa
77 muutettua tiedostoa jossa 73 lisäystä ja 142 poistoa
  1. 0
    1
      Marlin/Configuration_adv.h
  2. 1
    1
      Marlin/src/gcode/host/M115.cpp
  3. 72
    66
      Marlin/src/module/temperature.cpp
  4. 0
    1
      config/default/Configuration_adv.h
  5. 0
    1
      config/examples/3DFabXYZ/Migbot/Configuration_adv.h
  6. 0
    1
      config/examples/AlephObjects/TAZ4/Configuration_adv.h
  7. 0
    1
      config/examples/AliExpress/UM2pExt/Configuration_adv.h
  8. 0
    1
      config/examples/Anet/A2/Configuration_adv.h
  9. 0
    1
      config/examples/Anet/A2plus/Configuration_adv.h
  10. 0
    1
      config/examples/Anet/A6/Configuration_adv.h
  11. 0
    1
      config/examples/Anet/A8/Configuration_adv.h
  12. 0
    1
      config/examples/AnyCubic/i3/Configuration_adv.h
  13. 0
    1
      config/examples/ArmEd/Configuration_adv.h
  14. 0
    1
      config/examples/BIBO/TouchX/cyclops/Configuration_adv.h
  15. 0
    1
      config/examples/BIBO/TouchX/default/Configuration_adv.h
  16. 0
    1
      config/examples/BQ/Hephestos/Configuration_adv.h
  17. 0
    1
      config/examples/BQ/Hephestos_2/Configuration_adv.h
  18. 0
    1
      config/examples/BQ/WITBOX/Configuration_adv.h
  19. 0
    1
      config/examples/Cartesio/Configuration_adv.h
  20. 0
    1
      config/examples/Creality/CR-10/Configuration_adv.h
  21. 0
    1
      config/examples/Creality/CR-10S/Configuration_adv.h
  22. 0
    1
      config/examples/Creality/CR-10_5S/Configuration_adv.h
  23. 0
    1
      config/examples/Creality/CR-10mini/Configuration_adv.h
  24. 0
    1
      config/examples/Creality/CR-8/Configuration_adv.h
  25. 0
    1
      config/examples/Creality/Ender-2/Configuration_adv.h
  26. 0
    1
      config/examples/Creality/Ender-3/Configuration_adv.h
  27. 0
    1
      config/examples/Creality/Ender-4/Configuration_adv.h
  28. 0
    1
      config/examples/Einstart-S/Configuration_adv.h
  29. 0
    1
      config/examples/Felix/Configuration_adv.h
  30. 0
    1
      config/examples/FlashForge/CreatorPro/Configuration_adv.h
  31. 0
    1
      config/examples/FolgerTech/i3-2020/Configuration_adv.h
  32. 0
    1
      config/examples/Formbot/Raptor/Configuration_adv.h
  33. 0
    1
      config/examples/Formbot/T_Rex_2+/Configuration_adv.h
  34. 0
    1
      config/examples/Formbot/T_Rex_3/Configuration_adv.h
  35. 0
    1
      config/examples/Geeetech/A10M/Configuration_adv.h
  36. 0
    1
      config/examples/Geeetech/A20M/Configuration_adv.h
  37. 0
    1
      config/examples/Geeetech/MeCreator2/Configuration_adv.h
  38. 0
    1
      config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h
  39. 0
    1
      config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h
  40. 0
    1
      config/examples/Infitary/i3-M508/Configuration_adv.h
  41. 0
    1
      config/examples/JGAurora/A5/Configuration_adv.h
  42. 0
    1
      config/examples/MakerParts/Configuration_adv.h
  43. 0
    1
      config/examples/Malyan/M150/Configuration_adv.h
  44. 0
    1
      config/examples/Malyan/M200/Configuration_adv.h
  45. 0
    1
      config/examples/Micromake/C1/enhanced/Configuration_adv.h
  46. 0
    1
      config/examples/Mks/Robin/Configuration_adv.h
  47. 0
    1
      config/examples/Mks/Sbase/Configuration_adv.h
  48. 0
    1
      config/examples/RapideLite/RL200/Configuration_adv.h
  49. 0
    1
      config/examples/RigidBot/Configuration_adv.h
  50. 0
    1
      config/examples/SCARA/Configuration_adv.h
  51. 0
    1
      config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h
  52. 0
    1
      config/examples/Sanguinololu/Configuration_adv.h
  53. 0
    1
      config/examples/TheBorg/Configuration_adv.h
  54. 0
    1
      config/examples/TinyBoy2/Configuration_adv.h
  55. 0
    1
      config/examples/Tronxy/X3A/Configuration_adv.h
  56. 0
    1
      config/examples/Tronxy/X5S-2E/Configuration_adv.h
  57. 0
    1
      config/examples/UltiMachine/Archim1/Configuration_adv.h
  58. 0
    1
      config/examples/UltiMachine/Archim2/Configuration_adv.h
  59. 0
    1
      config/examples/VORONDesign/Configuration_adv.h
  60. 0
    1
      config/examples/Velleman/K8200/Configuration_adv.h
  61. 0
    1
      config/examples/Velleman/K8400/Configuration_adv.h
  62. 0
    1
      config/examples/WASP/PowerWASP/Configuration_adv.h
  63. 0
    1
      config/examples/Wanhao/Duplicator 6/Configuration_adv.h
  64. 0
    1
      config/examples/delta/Anycubic/Kossel/Configuration_adv.h
  65. 0
    1
      config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h
  66. 0
    1
      config/examples/delta/FLSUN/kossel/Configuration_adv.h
  67. 0
    1
      config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h
  68. 0
    1
      config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h
  69. 0
    1
      config/examples/delta/MKS/SBASE/Configuration_adv.h
  70. 0
    1
      config/examples/delta/Tevo Little Monster/Configuration_adv.h
  71. 0
    1
      config/examples/delta/generic/Configuration_adv.h
  72. 0
    1
      config/examples/delta/kossel_mini/Configuration_adv.h
  73. 0
    1
      config/examples/delta/kossel_xl/Configuration_adv.h
  74. 0
    1
      config/examples/gCreate/gMax1.5+/Configuration_adv.h
  75. 0
    1
      config/examples/makibox/Configuration_adv.h
  76. 0
    1
      config/examples/tvrrug/Round2/Configuration_adv.h
  77. 0
    1
      config/examples/wt150/Configuration_adv.h

+ 0
- 1
Marlin/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 1
- 1
Marlin/src/gcode/host/M115.cpp Näytä tiedosto

@@ -152,7 +152,7 @@ void GcodeSuite::M115() {
152 152
 
153 153
     // THERMAL_PROTECTION
154 154
     cap_line(PSTR("THERMAL_PROTECTION")
155
-      #if BOTH(THERMAL_PROTECTION_HOTENDS, THERMAL_PROTECTION_BED)
155
+      #if ENABLED(THERMAL_PROTECTION_HOTENDS) && (ENABLED(THERMAL_PROTECTION_BED) || !HAS_HEATED_BED) && (ENABLED(THERMAL_PROTECTION_CHAMBER) || !HAS_HEATED_CHAMBER)
156 156
         , true
157 157
       #endif
158 158
     );

+ 72
- 66
Marlin/src/module/temperature.cpp Näytä tiedosto

@@ -233,8 +233,8 @@ hotend_info_t Temperature::temp_hotend[HOTENDS]; // = { 0 }
233 233
     #endif
234 234
     #if WATCH_CHAMBER
235 235
       heater_watch_t Temperature::watch_chamber = { 0 };
236
-      millis_t Temperature::next_chamber_check_ms;
237 236
     #endif
237
+    millis_t Temperature::next_chamber_check_ms;
238 238
   #endif // HAS_HEATED_CHAMBER
239 239
 #endif // HAS_TEMP_CHAMBER
240 240
 
@@ -1058,56 +1058,61 @@ void Temperature::manage_heater() {
1058 1058
       }
1059 1059
     #endif // WATCH_BED
1060 1060
 
1061
-    #if DISABLED(PIDTEMPBED)
1062
-      if (PENDING(ms, next_bed_check_ms)
1061
+    do {
1062
+
1063
+      #if DISABLED(PIDTEMPBED)
1064
+        if (PENDING(ms, next_bed_check_ms)
1065
+          #if BOTH(PROBING_HEATERS_OFF, BED_LIMIT_SWITCHING)
1066
+            && paused == last_pause_state
1067
+          #endif
1068
+        ) break;
1069
+        next_bed_check_ms = ms + BED_CHECK_INTERVAL;
1063 1070
         #if BOTH(PROBING_HEATERS_OFF, BED_LIMIT_SWITCHING)
1064
-          && paused == last_pause_state
1071
+          last_pause_state = paused;
1065 1072
         #endif
1066
-      ) return;
1067
-      next_bed_check_ms = ms + BED_CHECK_INTERVAL;
1068
-      #if BOTH(PROBING_HEATERS_OFF, BED_LIMIT_SWITCHING)
1069
-        last_pause_state = paused;
1070 1073
       #endif
1071
-    #endif
1072 1074
 
1073
-    #if HEATER_IDLE_HANDLER
1074
-      bed_idle.update(ms);
1075
-    #endif
1075
+      #if HEATER_IDLE_HANDLER
1076
+        bed_idle.update(ms);
1077
+      #endif
1076 1078
 
1077
-    #if HAS_THERMALLY_PROTECTED_BED
1078
-      thermal_runaway_protection(tr_state_machine_bed, temp_bed.current, temp_bed.target, -1, THERMAL_PROTECTION_BED_PERIOD, THERMAL_PROTECTION_BED_HYSTERESIS);
1079
-    #endif
1079
+      #if HAS_THERMALLY_PROTECTED_BED
1080
+        thermal_runaway_protection(tr_state_machine_bed, temp_bed.current, temp_bed.target, -1, THERMAL_PROTECTION_BED_PERIOD, THERMAL_PROTECTION_BED_HYSTERESIS);
1081
+      #endif
1080 1082
 
1081
-    #if HEATER_IDLE_HANDLER
1082
-      if (bed_idle.timed_out) {
1083
-        temp_bed.soft_pwm_amount = 0;
1084
-        #if DISABLED(PIDTEMPBED)
1085
-          WRITE_HEATER_BED(LOW);
1086
-        #endif
1087
-      }
1088
-      else
1089
-    #endif
1090
-    {
1091
-      #if ENABLED(PIDTEMPBED)
1092
-        temp_bed.soft_pwm_amount = WITHIN(temp_bed.current, BED_MINTEMP, BED_MAXTEMP) ? (int)get_pid_output_bed() >> 1 : 0;
1093
-      #else
1094
-        // Check if temperature is within the correct band
1095
-        if (WITHIN(temp_bed.current, BED_MINTEMP, BED_MAXTEMP)) {
1096
-          #if ENABLED(BED_LIMIT_SWITCHING)
1097
-            if (temp_bed.current >= temp_bed.target + BED_HYSTERESIS)
1098
-              temp_bed.soft_pwm_amount = 0;
1099
-            else if (temp_bed.current <= temp_bed.target - (BED_HYSTERESIS))
1100
-              temp_bed.soft_pwm_amount = MAX_BED_POWER >> 1;
1101
-          #else // !PIDTEMPBED && !BED_LIMIT_SWITCHING
1102
-            temp_bed.soft_pwm_amount = temp_bed.current < temp_bed.target ? MAX_BED_POWER >> 1 : 0;
1103
-          #endif
1104
-        }
1105
-        else {
1083
+      #if HEATER_IDLE_HANDLER
1084
+        if (bed_idle.timed_out) {
1106 1085
           temp_bed.soft_pwm_amount = 0;
1107
-          WRITE_HEATER_BED(LOW);
1086
+          #if DISABLED(PIDTEMPBED)
1087
+            WRITE_HEATER_BED(LOW);
1088
+          #endif
1108 1089
         }
1090
+        else
1109 1091
       #endif
1110
-    }
1092
+      {
1093
+        #if ENABLED(PIDTEMPBED)
1094
+          temp_bed.soft_pwm_amount = WITHIN(temp_bed.current, BED_MINTEMP, BED_MAXTEMP) ? (int)get_pid_output_bed() >> 1 : 0;
1095
+        #else
1096
+          // Check if temperature is within the correct band
1097
+          if (WITHIN(temp_bed.current, BED_MINTEMP, BED_MAXTEMP)) {
1098
+            #if ENABLED(BED_LIMIT_SWITCHING)
1099
+              if (temp_bed.current >= temp_bed.target + BED_HYSTERESIS)
1100
+                temp_bed.soft_pwm_amount = 0;
1101
+              else if (temp_bed.current <= temp_bed.target - (BED_HYSTERESIS))
1102
+                temp_bed.soft_pwm_amount = MAX_BED_POWER >> 1;
1103
+            #else // !PIDTEMPBED && !BED_LIMIT_SWITCHING
1104
+              temp_bed.soft_pwm_amount = temp_bed.current < temp_bed.target ? MAX_BED_POWER >> 1 : 0;
1105
+            #endif
1106
+          }
1107
+          else {
1108
+            temp_bed.soft_pwm_amount = 0;
1109
+            WRITE_HEATER_BED(LOW);
1110
+          }
1111
+        #endif
1112
+      }
1113
+
1114
+    } while (false);
1115
+
1111 1116
   #endif // HAS_HEATED_BED
1112 1117
 
1113 1118
   #if HAS_HEATED_CHAMBER
@@ -1123,35 +1128,36 @@ void Temperature::manage_heater() {
1123 1128
 
1124 1129
     #if WATCH_CHAMBER
1125 1130
       // Make sure temperature is increasing
1126
-      if (watch_chamber.elapsed(ms)) {                  // Time to check the chamber?
1127
-        if (degChamber() < watch_chamber.target)   // Failed to increase enough?
1131
+      if (watch_chamber.elapsed(ms)) {              // Time to check the chamber?
1132
+        if (degChamber() < watch_chamber.target)    // Failed to increase enough?
1128 1133
           _temp_error(-2, PSTR(MSG_T_HEATING_FAILED), TEMP_ERR_PSTR(MSG_HEATING_FAILED_LCD, -2));
1129 1134
         else
1130
-          start_watching_chamber();                     // Start again if the target is still far off
1135
+          start_watching_chamber();                 // Start again if the target is still far off
1131 1136
       }
1132
-    #endif // WATCH_CHAMBER
1137
+    #endif
1133 1138
 
1134
-    if (PENDING(ms, next_chamber_check_ms)) return;
1135
-    next_chamber_check_ms = ms + CHAMBER_CHECK_INTERVAL;
1139
+    if (ELAPSED(ms, next_chamber_check_ms)) {
1140
+      next_chamber_check_ms = ms + CHAMBER_CHECK_INTERVAL;
1136 1141
 
1137
-    if (WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
1138
-      #if ENABLED(CHAMBER_LIMIT_SWITCHING)
1139
-        if (temp_chamber.current >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS)
1140
-          temp_chamber.soft_pwm_amount = 0;
1141
-        else if (temp_chamber.current <= temp_chamber.target - (TEMP_CHAMBER_HYSTERESIS))
1142
-          temp_chamber.soft_pwm_amount = MAX_CHAMBER_POWER >> 1;
1143
-      #else
1144
-        temp_chamber.soft_pwm_amount = temp_chamber.current < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0;
1142
+      if (WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
1143
+        #if ENABLED(CHAMBER_LIMIT_SWITCHING)
1144
+          if (temp_chamber.current >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS)
1145
+            temp_chamber.soft_pwm_amount = 0;
1146
+          else if (temp_chamber.current <= temp_chamber.target - (TEMP_CHAMBER_HYSTERESIS))
1147
+            temp_chamber.soft_pwm_amount = MAX_CHAMBER_POWER >> 1;
1148
+        #else
1149
+          temp_chamber.soft_pwm_amount = temp_chamber.current < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0;
1150
+        #endif
1151
+      }
1152
+      else {
1153
+        temp_chamber.soft_pwm_amount = 0;
1154
+        WRITE_HEATER_CHAMBER(LOW);
1155
+      }
1156
+
1157
+      #if ENABLED(THERMAL_PROTECTION_CHAMBER)
1158
+        thermal_runaway_protection(tr_state_machine_chamber, temp_chamber.current, temp_chamber.target, -2, THERMAL_PROTECTION_CHAMBER_PERIOD, THERMAL_PROTECTION_CHAMBER_HYSTERESIS);
1145 1159
       #endif
1146 1160
     }
1147
-    else {
1148
-      temp_chamber.soft_pwm_amount = 0;
1149
-      WRITE_HEATER_CHAMBER(LOW);
1150
-    }
1151
-
1152
-    #if ENABLED(THERMAL_PROTECTION_CHAMBER)
1153
-      thermal_runaway_protection(tr_state_machine_chamber, temp_chamber.current, temp_chamber.target, -2, THERMAL_PROTECTION_CHAMBER_PERIOD, THERMAL_PROTECTION_CHAMBER_HYSTERESIS);
1154
-    #endif
1155 1161
 
1156 1162
     // TODO: Implement true PID pwm
1157 1163
     //temp_bed.soft_pwm_amount = WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP) ? (int)get_pid_output_chamber() >> 1 : 0;
@@ -1788,8 +1794,8 @@ void Temperature::init() {
1788 1794
 
1789 1795
 #if WATCH_CHAMBER
1790 1796
   /**
1791
-   * Start Heating Sanity Check for hotends that are below
1792
-   * their target temperature by a configurable margin.
1797
+   * Start Heating Sanity Check for chamber that is below
1798
+   * its target temperature by a configurable margin.
1793 1799
    * This is called when the temperature is set. (M141, M191)
1794 1800
    */
1795 1801
   void Temperature::start_watching_chamber() {

+ 0
- 1
config/default/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/3DFabXYZ/Migbot/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/AlephObjects/TAZ4/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/AliExpress/UM2pExt/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Anet/A2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Anet/A2plus/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Anet/A6/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Anet/A8/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/AnyCubic/i3/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/ArmEd/Configuration_adv.h Näytä tiedosto

@@ -112,7 +112,6 @@
112 112
   #define CHAMBER_MINTEMP             5
113 113
   #define CHAMBER_MAXTEMP            60
114 114
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
115
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
116 115
   //#define CHAMBER_LIMIT_SWITCHING
117 116
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
118 117
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/BIBO/TouchX/cyclops/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/BIBO/TouchX/default/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/BQ/Hephestos/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/BQ/Hephestos_2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/BQ/WITBOX/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Cartesio/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/CR-10/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/CR-10S/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/CR-10_5S/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/CR-10mini/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/CR-8/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/Ender-2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/Ender-3/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Creality/Ender-4/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Einstart-S/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Felix/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/FlashForge/CreatorPro/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/FolgerTech/i3-2020/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Formbot/Raptor/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Formbot/T_Rex_2+/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Formbot/T_Rex_3/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Geeetech/A10M/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Geeetech/A20M/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Geeetech/MeCreator2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Geeetech/Prusa i3 Pro C/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Geeetech/Prusa i3 Pro W/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Infitary/i3-M508/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/JGAurora/A5/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/MakerParts/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Malyan/M150/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Malyan/M200/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Micromake/C1/enhanced/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Mks/Robin/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Mks/Sbase/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/RapideLite/RL200/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/RigidBot/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/SCARA/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/STM32/Black_STM32F407VET6/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Sanguinololu/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/TheBorg/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/TinyBoy2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Tronxy/X3A/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Tronxy/X5S-2E/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/UltiMachine/Archim1/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/UltiMachine/Archim2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/VORONDesign/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Velleman/K8200/Configuration_adv.h Näytä tiedosto

@@ -117,7 +117,6 @@
117 117
   #define CHAMBER_MINTEMP             5
118 118
   #define CHAMBER_MAXTEMP            60
119 119
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
120
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
121 120
   //#define CHAMBER_LIMIT_SWITCHING
122 121
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
123 122
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Velleman/K8400/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/WASP/PowerWASP/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/Wanhao/Duplicator 6/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/Anycubic/Kossel/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/FLSUN/auto_calibrate/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/FLSUN/kossel/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/FLSUN/kossel_mini/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/Geeetech/Rostock 301/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/MKS/SBASE/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/Tevo Little Monster/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/generic/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/kossel_mini/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/delta/kossel_xl/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/gCreate/gMax1.5+/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/makibox/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/tvrrug/Round2/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

+ 0
- 1
config/examples/wt150/Configuration_adv.h Näytä tiedosto

@@ -108,7 +108,6 @@
108 108
   #define CHAMBER_MINTEMP             5
109 109
   #define CHAMBER_MAXTEMP            60
110 110
   #define TEMP_CHAMBER_HYSTERESIS     1   // (°C) Temperature proximity considered "close enough" to the target
111
-  #define THERMAL_PROTECTION_CHAMBER      // Enable thermal protection for the heated chamber
112 111
   //#define CHAMBER_LIMIT_SWITCHING
113 112
   //#define HEATER_CHAMBER_PIN       44   // Chamber heater on/off pin
114 113
   //#define HEATER_CHAMBER_INVERTING false

Loading…
Peruuta
Tallenna