Procházet zdrojové kódy

Dummy Thermistor Table for testing purposes

Am I the only one who always need to change the thermistortable.h to add
a dummy table??
Ok, it is done. Just set the thermistor to 999 and it will always read
25C. Great for Testing or Development purposes.
alexborro před 9 roky
rodič
revize
a57869ba49
2 změnil soubory, kde provedl 11 přidání a 0 odebrání
  1. 1
    0
      Marlin/Configuration.h
  2. 10
    0
      Marlin/thermistortables.h

+ 1
- 0
Marlin/Configuration.h Zobrazit soubor

@@ -118,6 +118,7 @@ Here are some standard links for getting your machine calibrated:
118 118
 // 1010 is Pt1000 with 1k pullup (non standard)
119 119
 // 147 is Pt100 with 4k7 pullup
120 120
 // 110 is Pt100 with 1k pullup (non standard)
121
+// 999 is a Dummy Table. It will ALWAYS read 25C.. Use it for Testing or Development purposes. NEVER for production machine.
121 122
 
122 123
 #define TEMP_SENSOR_0 -1
123 124
 #define TEMP_SENSOR_1 -1

+ 10
- 0
Marlin/thermistortables.h Zobrazit soubor

@@ -1095,6 +1095,16 @@ const short temptable_1047[][2] PROGMEM = {
1095 1095
 };
1096 1096
 #endif
1097 1097
 
1098
+#if (THERMISTORHEATER_0 == 999) || (THERMISTORHEATER_1 == 999) || (THERMISTORHEATER_2 == 999) || (THERMISTORHEATER_3 == 999) || (THERMISTORBED == 999) //User defined table
1099
+// Dummy Thermistor table.. It will ALWAYS read 25C.
1100
+const short temptable_999[][2] PROGMEM = {
1101
+   {1*OVERSAMPLENR, 25},
1102
+   {1023*OVERSAMPLENR, 25}
1103
+};
1104
+#endif
1105
+
1106
+
1107
+
1098 1108
 #define _TT_NAME(_N) temptable_ ## _N
1099 1109
 #define TT_NAME(_N) _TT_NAME(_N)
1100 1110
 

Loading…
Zrušit