Bläddra i källkod

Goodbye MECHANICAL_PROBE

Scott Lahteine 8 år sedan
förälder
incheckning
bd01592816

+ 2
- 2
.travis.yml Visa fil

@@ -101,10 +101,10 @@ script:
101 101
   - opt_enable AUTO_BED_LEVELING_FEATURE DEBUG_LEVELING_FEATURE
102 102
   - build_marlin
103 103
   #
104
-  # Test a Mechanical Probe
104
+  # Test a Sled Z Probe
105 105
   #
106 106
   - restore_configs
107
-  - opt_enable MECHANICAL_PROBE
107
+  - opt_enable Z_PROBE_SLED
108 108
   - build_marlin
109 109
   #
110 110
   # ...with AUTO_BED_LEVELING_FEATURE & DEBUG_LEVELING_FEATURE

+ 1
- 1
Marlin/Conditionals.h Visa fil

@@ -752,7 +752,7 @@
752 752
     #endif
753 753
   #endif
754 754
 
755
-  #define PROBE_SELECTED (ENABLED(FIX_MOUNTED_PROBE) || ENABLED(MECHANICAL_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))
755
+  #define PROBE_SELECTED (ENABLED(FIX_MOUNTED_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))
756 756
 
757 757
   #define PROBE_PIN_CONFIGURED (HAS_Z_MIN_PROBE_PIN || (HAS_Z_MIN && ENABLED(Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN)))
758 758
 

+ 4
- 6
Marlin/Configuration.h Visa fil

@@ -419,8 +419,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
419 419
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
420 420
 //
421 421
 
422
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
423
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
422
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
423
+// For example an inductive probe, or a setup that uses the nozzle to probe.
424
+// An inductive probe must be deactivated to go below
425
+// its trigger-point if hardware endstops are active.
424 426
 //#define FIX_MOUNTED_PROBE
425 427
 
426 428
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -431,10 +433,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
431 433
 //#define Z_PROBE_SLED
432 434
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
433 435
 
434
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
435
-// For example any setup that uses the nozzle itself as a probe.
436
-//#define MECHANICAL_PROBE
437
-
438 436
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
439 437
 // X and Y offsets must be integers.
440 438
 //

+ 2
- 2
Marlin/Marlin_main.cpp Visa fil

@@ -1890,7 +1890,7 @@ static void clean_up_after_endstop_or_probe_move() {
1890 1890
           stop();
1891 1891
         }
1892 1892
 
1893
-    #elif ENABLED(FIX_MOUNTED_PROBE)
1893
+    #else
1894 1894
 
1895 1895
       // Nothing to be done. Just enable_z_probe below...
1896 1896
 
@@ -1982,7 +1982,7 @@ static void clean_up_after_endstop_or_probe_move() {
1982 1982
           stop();
1983 1983
         }
1984 1984
 
1985
-    #elif ENABLED(FIX_MOUNTED_PROBE)
1985
+    #else
1986 1986
 
1987 1987
       // Nothing to do here. Just clear endstops.z_probe_enabled
1988 1988
 

+ 4
- 5
Marlin/SanityCheck.h Visa fil

@@ -268,11 +268,10 @@
268 268
   /**
269 269
    * Only allow one probe option to be defined
270 270
    */
271
-  #if (ENABLED(FIX_MOUNTED_PROBE) && (ENABLED(MECHANICAL_PROBE) || ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))) \
272
-       || (ENABLED(MECHANICAL_PROBE) && (ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))) \
271
+  #if (ENABLED(FIX_MOUNTED_PROBE) && (ENABLED(Z_PROBE_ALLEN_KEY) || HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))) \
273 272
        || (ENABLED(Z_PROBE_ALLEN_KEY) && (HAS_Z_SERVO_ENDSTOP || ENABLED(Z_PROBE_SLED))) \
274 273
        || (HAS_Z_SERVO_ENDSTOP && ENABLED(Z_PROBE_SLED))
275
-    #error "Please define only one type of probe: Z Servo, MECHANICAL_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
274
+    #error "Please define only one type of probe: Z Servo, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
276 275
   #endif
277 276
 
278 277
   /**
@@ -314,9 +313,9 @@
314 313
    * Require some kind of probe for bed leveling and probe testing
315 314
    */
316 315
   #if ENABLED(AUTO_BED_LEVELING_FEATURE)
317
-    #error "AUTO_BED_LEVELING_FEATURE requires a probe! Define a Z Servo, MECHANICAL_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
316
+    #error "AUTO_BED_LEVELING_FEATURE requires a probe! Define a Z Servo, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
318 317
   #elif ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
319
-    #error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe! Define a Z Servo, MECHANICAL_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
318
+    #error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe! Define a Z Servo, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
320 319
   #endif
321 320
 
322 321
 #endif

+ 4
- 6
Marlin/example_configurations/Cartesio/Configuration.h Visa fil

@@ -418,8 +418,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
418 418
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
419 419
 //
420 420
 
421
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
422
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
421
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
422
+// For example an inductive probe, or a setup that uses the nozzle to probe.
423
+// An inductive probe must be deactivated to go below
424
+// its trigger-point if hardware endstops are active.
423 425
 //#define FIX_MOUNTED_PROBE
424 426
 
425 427
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -430,10 +432,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
430 432
 //#define Z_PROBE_SLED
431 433
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
432 434
 
433
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
434
-// For example any setup that uses the nozzle itself as a probe.
435
-//#define MECHANICAL_PROBE
436
-
437 435
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
438 436
 // X and Y offsets must be integers.
439 437
 //

+ 4
- 6
Marlin/example_configurations/Felix/Configuration.h Visa fil

@@ -401,8 +401,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
401 401
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
402 402
 //
403 403
 
404
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
405
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
404
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
405
+// For example an inductive probe, or a setup that uses the nozzle to probe.
406
+// An inductive probe must be deactivated to go below
407
+// its trigger-point if hardware endstops are active.
406 408
 //#define FIX_MOUNTED_PROBE
407 409
 
408 410
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -413,10 +415,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
413 415
 //#define Z_PROBE_SLED
414 416
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
415 417
 
416
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
417
-// For example any setup that uses the nozzle itself as a probe.
418
-//#define MECHANICAL_PROBE
419
-
420 418
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
421 419
 // X and Y offsets must be integers.
422 420
 //

+ 4
- 6
Marlin/example_configurations/Felix/DUAL/Configuration.h Visa fil

@@ -399,8 +399,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
399 399
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
400 400
 //
401 401
 
402
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
403
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
402
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
403
+// For example an inductive probe, or a setup that uses the nozzle to probe.
404
+// An inductive probe must be deactivated to go below
405
+// its trigger-point if hardware endstops are active.
404 406
 //#define FIX_MOUNTED_PROBE
405 407
 
406 408
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -411,10 +413,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
411 413
 //#define Z_PROBE_SLED
412 414
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
413 415
 
414
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
415
-// For example any setup that uses the nozzle itself as a probe.
416
-//#define MECHANICAL_PROBE
417
-
418 416
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
419 417
 // X and Y offsets must be integers.
420 418
 //

+ 4
- 6
Marlin/example_configurations/Hephestos/Configuration.h Visa fil

@@ -411,8 +411,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
411 411
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
412 412
 //
413 413
 
414
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
415
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
414
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
415
+// For example an inductive probe, or a setup that uses the nozzle to probe.
416
+// An inductive probe must be deactivated to go below
417
+// its trigger-point if hardware endstops are active.
416 418
 //#define FIX_MOUNTED_PROBE
417 419
 
418 420
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -423,10 +425,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
423 425
 //#define Z_PROBE_SLED
424 426
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
425 427
 
426
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
427
-// For example any setup that uses the nozzle itself as a probe.
428
-//#define MECHANICAL_PROBE
429
-
430 428
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
431 429
 // X and Y offsets must be integers.
432 430
 //

+ 4
- 6
Marlin/example_configurations/Hephestos_2/Configuration.h Visa fil

@@ -413,8 +413,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
413 413
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
414 414
 //
415 415
 
416
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
417
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
416
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
417
+// For example an inductive probe, or a setup that uses the nozzle to probe.
418
+// An inductive probe must be deactivated to go below
419
+// its trigger-point if hardware endstops are active.
418 420
 #define FIX_MOUNTED_PROBE
419 421
 
420 422
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -425,10 +427,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
425 427
 //#define Z_PROBE_SLED
426 428
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
427 429
 
428
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
429
-// For example any setup that uses the nozzle itself as a probe.
430
-//#define MECHANICAL_PROBE
431
-
432 430
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
433 431
 // X and Y offsets must be integers.
434 432
 //

+ 4
- 6
Marlin/example_configurations/K8200/Configuration.h Visa fil

@@ -436,8 +436,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
436 436
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
437 437
 //
438 438
 
439
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
440
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
439
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
440
+// For example an inductive probe, or a setup that uses the nozzle to probe.
441
+// An inductive probe must be deactivated to go below
442
+// its trigger-point if hardware endstops are active.
441 443
 //#define FIX_MOUNTED_PROBE
442 444
 
443 445
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -448,10 +450,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
448 450
 //#define Z_PROBE_SLED
449 451
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
450 452
 
451
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
452
-// For example any setup that uses the nozzle itself as a probe.
453
-//#define MECHANICAL_PROBE
454
-
455 453
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
456 454
 // X and Y offsets must be integers.
457 455
 //

+ 4
- 6
Marlin/example_configurations/RepRapWorld/Megatronics/Configuration.h Visa fil

@@ -419,8 +419,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
419 419
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
420 420
 //
421 421
 
422
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
423
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
422
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
423
+// For example an inductive probe, or a setup that uses the nozzle to probe.
424
+// An inductive probe must be deactivated to go below
425
+// its trigger-point if hardware endstops are active.
424 426
 //#define FIX_MOUNTED_PROBE
425 427
 
426 428
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -431,10 +433,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
431 433
 //#define Z_PROBE_SLED
432 434
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
433 435
 
434
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
435
-// For example any setup that uses the nozzle itself as a probe.
436
-//#define MECHANICAL_PROBE
437
-
438 436
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
439 437
 // X and Y offsets must be integers.
440 438
 //

+ 4
- 6
Marlin/example_configurations/RigidBot/Configuration.h Visa fil

@@ -413,8 +413,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
413 413
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
414 414
 //
415 415
 
416
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
417
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
416
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
417
+// For example an inductive probe, or a setup that uses the nozzle to probe.
418
+// An inductive probe must be deactivated to go below
419
+// its trigger-point if hardware endstops are active.
418 420
 //#define FIX_MOUNTED_PROBE
419 421
 
420 422
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -425,10 +427,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
425 427
 //#define Z_PROBE_SLED
426 428
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
427 429
 
428
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
429
-// For example any setup that uses the nozzle itself as a probe.
430
-//#define MECHANICAL_PROBE
431
-
432 430
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
433 431
 // X and Y offsets must be integers.
434 432
 //

+ 4
- 6
Marlin/example_configurations/SCARA/Configuration.h Visa fil

@@ -427,8 +427,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
427 427
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
428 428
 //
429 429
 
430
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
431
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
430
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
431
+// For example an inductive probe, or a setup that uses the nozzle to probe.
432
+// An inductive probe must be deactivated to go below
433
+// its trigger-point if hardware endstops are active.
432 434
 //#define FIX_MOUNTED_PROBE
433 435
 
434 436
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -439,10 +441,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
439 441
 //#define Z_PROBE_SLED
440 442
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
441 443
 
442
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
443
-// For example any setup that uses the nozzle itself as a probe.
444
-//#define MECHANICAL_PROBE
445
-
446 444
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
447 445
 // X and Y offsets must be integers.
448 446
 //

+ 4
- 6
Marlin/example_configurations/TAZ4/Configuration.h Visa fil

@@ -440,8 +440,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
440 440
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
441 441
 //
442 442
 
443
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
444
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
443
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
444
+// For example an inductive probe, or a setup that uses the nozzle to probe.
445
+// An inductive probe must be deactivated to go below
446
+// its trigger-point if hardware endstops are active.
445 447
 //#define FIX_MOUNTED_PROBE
446 448
 
447 449
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -452,10 +454,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
452 454
 //#define Z_PROBE_SLED
453 455
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
454 456
 
455
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
456
-// For example any setup that uses the nozzle itself as a probe.
457
-//#define MECHANICAL_PROBE
458
-
459 457
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
460 458
 // X and Y offsets must be integers.
461 459
 //

+ 4
- 6
Marlin/example_configurations/WITBOX/Configuration.h Visa fil

@@ -411,8 +411,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
411 411
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
412 412
 //
413 413
 
414
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
415
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
414
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
415
+// For example an inductive probe, or a setup that uses the nozzle to probe.
416
+// An inductive probe must be deactivated to go below
417
+// its trigger-point if hardware endstops are active.
416 418
 //#define FIX_MOUNTED_PROBE
417 419
 
418 420
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -423,10 +425,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
423 425
 //#define Z_PROBE_SLED
424 426
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
425 427
 
426
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
427
-// For example any setup that uses the nozzle itself as a probe.
428
-//#define MECHANICAL_PROBE
429
-
430 428
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
431 429
 // X and Y offsets must be integers.
432 430
 //

+ 4
- 6
Marlin/example_configurations/adafruit/ST7565/Configuration.h Visa fil

@@ -419,8 +419,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
419 419
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
420 420
 //
421 421
 
422
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
423
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
422
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
423
+// For example an inductive probe, or a setup that uses the nozzle to probe.
424
+// An inductive probe must be deactivated to go below
425
+// its trigger-point if hardware endstops are active.
424 426
 //#define FIX_MOUNTED_PROBE
425 427
 
426 428
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -431,10 +433,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
431 433
 //#define Z_PROBE_SLED
432 434
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
433 435
 
434
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
435
-// For example any setup that uses the nozzle itself as a probe.
436
-//#define MECHANICAL_PROBE
437
-
438 436
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
439 437
 // X and Y offsets must be integers.
440 438
 //

+ 4
- 6
Marlin/example_configurations/delta/biv2.5/Configuration.h Visa fil

@@ -461,8 +461,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
461 461
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
462 462
 //
463 463
 
464
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
465
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
464
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
465
+// For example an inductive probe, or a setup that uses the nozzle to probe.
466
+// An inductive probe must be deactivated to go below
467
+// its trigger-point if hardware endstops are active.
466 468
 //#define FIX_MOUNTED_PROBE
467 469
 
468 470
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -473,10 +475,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
473 475
 //#define Z_PROBE_SLED
474 476
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
475 477
 
476
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
477
-// For example any setup that uses the nozzle itself as a probe.
478
-//#define MECHANICAL_PROBE
479
-
480 478
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
481 479
 // X and Y offsets must be integers.
482 480
 //

+ 4
- 6
Marlin/example_configurations/delta/generic/Configuration.h Visa fil

@@ -461,8 +461,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
461 461
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
462 462
 //
463 463
 
464
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
465
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
464
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
465
+// For example an inductive probe, or a setup that uses the nozzle to probe.
466
+// An inductive probe must be deactivated to go below
467
+// its trigger-point if hardware endstops are active.
466 468
 //#define FIX_MOUNTED_PROBE
467 469
 
468 470
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -473,10 +475,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
473 475
 //#define Z_PROBE_SLED
474 476
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
475 477
 
476
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
477
-// For example any setup that uses the nozzle itself as a probe.
478
-//#define MECHANICAL_PROBE
479
-
480 478
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
481 479
 // X and Y offsets must be integers.
482 480
 //

+ 4
- 6
Marlin/example_configurations/delta/kossel_mini/Configuration.h Visa fil

@@ -461,8 +461,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
461 461
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
462 462
 //
463 463
 
464
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
465
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
464
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
465
+// For example an inductive probe, or a setup that uses the nozzle to probe.
466
+// An inductive probe must be deactivated to go below
467
+// its trigger-point if hardware endstops are active.
466 468
 //#define FIX_MOUNTED_PROBE
467 469
 
468 470
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -473,10 +475,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
473 475
 //#define Z_PROBE_SLED
474 476
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
475 477
 
476
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
477
-// For example any setup that uses the nozzle itself as a probe.
478
-//#define MECHANICAL_PROBE
479
-
480 478
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
481 479
 // X and Y offsets must be integers.
482 480
 //

+ 4
- 6
Marlin/example_configurations/delta/kossel_pro/Configuration.h Visa fil

@@ -450,8 +450,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
450 450
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
451 451
 //
452 452
 
453
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
454
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
453
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
454
+// For example an inductive probe, or a setup that uses the nozzle to probe.
455
+// An inductive probe must be deactivated to go below
456
+// its trigger-point if hardware endstops are active.
455 457
 //#define FIX_MOUNTED_PROBE
456 458
 
457 459
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -462,10 +464,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
462 464
 //#define Z_PROBE_SLED
463 465
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
464 466
 
465
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
466
-// For example any setup that uses the nozzle itself as a probe.
467
-//#define MECHANICAL_PROBE
468
-
469 467
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
470 468
 // X and Y offsets must be integers.
471 469
 //

+ 4
- 6
Marlin/example_configurations/delta/kossel_xl/Configuration.h Visa fil

@@ -459,8 +459,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
459 459
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
460 460
 //
461 461
 
462
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
463
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
462
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
463
+// For example an inductive probe, or a setup that uses the nozzle to probe.
464
+// An inductive probe must be deactivated to go below
465
+// its trigger-point if hardware endstops are active.
464 466
 #define FIX_MOUNTED_PROBE
465 467
 
466 468
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -471,10 +473,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
471 473
 //#define Z_PROBE_SLED
472 474
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
473 475
 
474
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
475
-// For example any setup that uses the nozzle itself as a probe.
476
-//#define MECHANICAL_PROBE
477
-
478 476
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
479 477
 // X and Y offsets must be integers.
480 478
 //

+ 4
- 6
Marlin/example_configurations/makibox/Configuration.h Visa fil

@@ -422,8 +422,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
422 422
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
423 423
 //
424 424
 
425
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
426
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
425
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
426
+// For example an inductive probe, or a setup that uses the nozzle to probe.
427
+// An inductive probe must be deactivated to go below
428
+// its trigger-point if hardware endstops are active.
427 429
 //#define FIX_MOUNTED_PROBE
428 430
 
429 431
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -434,10 +436,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the l
434 436
 //#define Z_PROBE_SLED
435 437
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
436 438
 
437
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
438
-// For example any setup that uses the nozzle itself as a probe.
439
-//#define MECHANICAL_PROBE
440
-
441 439
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
442 440
 // X and Y offsets must be integers.
443 441
 //

+ 4
- 6
Marlin/example_configurations/tvrrug/Round2/Configuration.h Visa fil

@@ -409,8 +409,10 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
409 409
 // Use M851 to set the Z probe vertical offset from the nozzle. Store with M500.
410 410
 //
411 411
 
412
-// A fix mounted probe, like the normal inductive probe, must be deactivated to go
413
-// below Z_PROBE_OFFSET_FROM_EXTRUDER when the hardware endstops are active.
412
+// A Fix-Mounted Probe either doesn't deploy or needs manual deployment.
413
+// For example an inductive probe, or a setup that uses the nozzle to probe.
414
+// An inductive probe must be deactivated to go below
415
+// its trigger-point if hardware endstops are active.
414 416
 //#define FIX_MOUNTED_PROBE
415 417
 
416 418
 // Z Servo Probe, such as an endstop switch on a rotating arm.
@@ -421,10 +423,6 @@ const bool Z_MIN_PROBE_ENDSTOP_INVERTING = true; // set to true to invert the lo
421 423
 //#define Z_PROBE_SLED
422 424
 //#define SLED_DOCKING_OFFSET 5 // The extra distance the X axis must travel to pickup the sled. 0 should be fine but you can push it further if you'd like.
423 425
 
424
-// A Mechanical Probe is any probe that either doesn't deploy or needs manual deployment
425
-// For example any setup that uses the nozzle itself as a probe.
426
-//#define MECHANICAL_PROBE
427
-
428 426
 // Z Probe to nozzle (X,Y) offset, relative to (0, 0).
429 427
 // X and Y offsets must be integers.
430 428
 //

Laddar…
Avbryt
Spara