Преглед изворни кода

Sensor 502 and PTC cleanup

Scott Lahteine пре 4 година
родитељ
комит
caeba33d28
2 измењених фајлова са 11 додато и 10 уклоњено
  1. 1
    0
      Marlin/Configuration.h
  2. 10
    10
      Marlin/Configuration_adv.h

+ 1
- 0
Marlin/Configuration.h Прегледај датотеку

@@ -373,6 +373,7 @@
373 373
  *     4 : 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
374 374
  *     5 : 100K thermistor - ATC Semitec 104GT-2/104NT-4-R025H42G (Used in ParCan, J-Head, and E3D) (4.7k pullup)
375 375
  *   501 : 100K Zonestar (Tronxy X3A) Thermistor
376
+ *   502 : 100K Zonestar Thermistor used by hot bed in Zonestar Prusa P802M
376 377
  *   512 : 100k RPW-Ultra hotend thermistor (4.7k pullup)
377 378
  *     6 : 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
378 379
  *     7 : 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)

+ 10
- 10
Marlin/Configuration_adv.h Прегледај датотеку

@@ -1666,33 +1666,33 @@
1666 1666
     // Probe temperature calibration generates a table of values starting at PTC_SAMPLE_START
1667 1667
     // (e.g. 30), in steps of PTC_SAMPLE_RES (e.g. 5) with PTC_SAMPLE_COUNT (e.g. 10) samples.
1668 1668
 
1669
-    // #define PTC_SAMPLE_START  30.0f
1670
-    // #define PTC_SAMPLE_RES    5.0f
1671
-    // #define PTC_SAMPLE_COUNT  10U
1669
+    //#define PTC_SAMPLE_START  30.0f
1670
+    //#define PTC_SAMPLE_RES    5.0f
1671
+    //#define PTC_SAMPLE_COUNT  10U
1672 1672
 
1673 1673
     // Bed temperature calibration builds a similar table.
1674 1674
 
1675
-    // #define BTC_SAMPLE_START  60.0f
1676
-    // #define BTC_SAMPLE_RES    5.0f
1677
-    // #define BTC_SAMPLE_COUNT  10U
1675
+    //#define BTC_SAMPLE_START  60.0f
1676
+    //#define BTC_SAMPLE_RES    5.0f
1677
+    //#define BTC_SAMPLE_COUNT  10U
1678 1678
 
1679 1679
     // The temperature the probe should be at while taking measurements during bed temperature
1680 1680
     // calibration.
1681
-    // #define BTC_PROBE_TEMP 30.0f
1681
+    //#define BTC_PROBE_TEMP 30.0f
1682 1682
 
1683 1683
     // Height above Z=0.0f to raise the nozzle. Lowering this can help the probe to heat faster.
1684 1684
     // Note: the Z=0.0f offset is determined by the probe offset which can be set using M851.
1685
-    // #define PTC_PROBE_HEATING_OFFSET 0.5f
1685
+    //#define PTC_PROBE_HEATING_OFFSET 0.5f
1686 1686
 
1687 1687
     // Height to raise the Z-probe between heating and taking the next measurement. Some probes
1688 1688
     // may fail to untrigger if they have been triggered for a long time, which can be solved by
1689 1689
     // increasing the height the probe is raised to.
1690
-    // #define PTC_PROBE_RAISE 15U
1690
+    //#define PTC_PROBE_RAISE 15U
1691 1691
 
1692 1692
     // If the probe is outside of the defined range, use linear extrapolation using the closest
1693 1693
     // point and the PTC_LINEAR_EXTRAPOLATION'th next point. E.g. if set to 4 it will use data[0]
1694 1694
     // and data[4] to perform linear extrapolation for values below PTC_SAMPLE_START.
1695
-    // #define PTC_LINEAR_EXTRAPOLATION 4
1695
+    //#define PTC_LINEAR_EXTRAPOLATION 4
1696 1696
   #endif
1697 1697
 #endif
1698 1698
 

Loading…
Откажи
Сачувај