@@ -215,7 +215,7 @@ Here are some standard links for getting your machine calibrated:
|
215
|
215
|
// If your configuration is significantly different than this and you don't understand the issues involved, you probably
|
216
|
216
|
// shouldn't use bed PID until someone else verifies your hardware works.
|
217
|
217
|
// If this is enabled, find your own PID constants below.
|
218
|
|
-//#define PIDTEMPBED
|
|
218
|
+#define PIDTEMPBED
|
219
|
219
|
//
|
220
|
220
|
//#define BED_LIMIT_SWITCHING
|
221
|
221
|
|
|
@@ -226,17 +226,10 @@ Here are some standard links for getting your machine calibrated:
|
226
|
226
|
#define MAX_BED_POWER 255 // limits duty cycle to bed; 255=full current
|
227
|
227
|
|
228
|
228
|
#ifdef PIDTEMPBED
|
229
|
|
-//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
230
|
|
-//from FOPDT model - kp=.39 Tp=405 Tdead=66, Tc set to 79.2, aggressive factor of .15 (vs .1, 1, 10)
|
231
|
|
- #define DEFAULT_bedKp 10.00
|
232
|
|
- #define DEFAULT_bedKi .023
|
233
|
|
- #define DEFAULT_bedKd 305.4
|
234
|
|
-
|
235
|
|
-//120v 250W silicone heater into 4mm borosilicate (MendelMax 1.5+)
|
236
|
|
-//from pidautotune
|
237
|
|
-// #define DEFAULT_bedKp 97.1
|
238
|
|
-// #define DEFAULT_bedKi 1.41
|
239
|
|
-// #define DEFAULT_bedKd 1675.16
|
|
229
|
+// Felix Foil Heater
|
|
230
|
+ #define DEFAULT_bedKp 103.37
|
|
231
|
+ #define DEFAULT_bedKi 2.79
|
|
232
|
+ #define DEFAULT_bedKd 956.94
|
240
|
233
|
|
241
|
234
|
// FIND YOUR OWN: "M303 E-1 C8 S90" to run autotune on the bed at 90 degreesC for 8 cycles.
|
242
|
235
|
#endif // PIDTEMPBED
|
|
@@ -280,15 +273,15 @@ your extruder heater takes 2 minutes to hit the target on heating.
|
280
|
273
|
// uncomment the 2 defines below:
|
281
|
274
|
|
282
|
275
|
// Parameters for all extruder heaters
|
283
|
|
-//#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
|
284
|
|
-//#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
|
276
|
+#define THERMAL_RUNAWAY_PROTECTION_PERIOD 60 //in seconds
|
|
277
|
+#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 5 // in degree Celsius
|
285
|
278
|
|
286
|
279
|
// If you want to enable this feature for your bed heater,
|
287
|
280
|
// uncomment the 2 defines below:
|
288
|
281
|
|
289
|
282
|
// Parameters for the bed heater
|
290
|
|
-//#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
|
291
|
|
-//#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
|
283
|
+#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 30 //in seconds
|
|
284
|
+#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 5// in degree Celsius
|
292
|
285
|
|
293
|
286
|
|
294
|
287
|
//===========================================================================
|