Send a Busy signal to hosts during long processes, wait for input, etc
If Marlin is blocking the serial input or command queue for any length
of time (for example more than 2 seconds), it needs to send a message
to serial out to inform the host that it is busy. Marlin should only
send these messages out when busy, and preferably not when trying to
print formatted output.
Don't override SOURCE_CODE_URL in Default_Version.h
- Defining `SOURCE_CODE_URL` in `Default_Version.h` overrides it
elsewhere. So don’t define it there.
- Also fix up `language.h` so no `#undef` will be needed.
Now send only temperature for T or B, but not send OK.
Host interprets the line to show the right temperature, but not in
response to M105 then stop and send commands until it ends the autotune.
- Use `setTargetedHotend` in `M200`, as with other commands that use
`T` for the extruder
- Synthesize the "invalid extruder" message, obviating several long
strings
Use _temp_error() for all errors thrown by different mechanisms
Now ending in an endless loop.
Tidy up the output format.
We now get:
ERRORTEXT ", system stopped! Heater_ID: " HEATERID
Where ERRORTEXT can be:
"Heating failed"
"Thermal Runaway"
"MAXTEMP triggered"
"MINTEMP triggered"
and soon
"Thermal Jump"
HEATERID can be
0, 1, 2 ,3 , "bed"
This messages are always followed by the common:
"Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
Edited the European part of 'ISO10646_CN.fon' to match the existing fonts.
Added Chinese font to make_fonts.bat
Created 'dogm_font_data_ISO10646_CN.h'
Added Chinese to 'language.h'
Added 'language_cn.h' with some minor edits.
Added Chinese font in 'language_en.h' to not fall back to European font.
Added cn to 'Configuration.h'
Changed WIDTH to LCD_PIXEL_WIDTH and HEIGHT to LCD_PIXEL_HEIGHT to have more descriptive names.
In 'dogm_lcd_implementation.h'
Added Chinese Font
Made 1 pixel more room for the larger Chinese font on the status line.
Changed geometry of the 'select bar' by one pixel.
Changed the way the position for values and postcars are set.
With these changes the output of `M503 S0` is all you need to restore
the EEPROM. Building on this it is straightforward to save and restore
the EEPROM state using the SD card or external GCode file.
- Added `M145` to set “heatup states” for the LCD menu
- Added `M420` to toggle Mesh Bed Leveling
- Added `M421` to set a single Mesh coordinate
- Extended `Config_PrintSettings` with added M codes
- Cleaned up some comments here and there
- Add `M111` as a standard option to set the debug level
- Implement `DEBUG_ECHO` in `process_commands`
- Other debug levels (e.g., `DEBUG_DRYRUN`) need more work
The automatic versioning system extracts a
build version number from the SCM system
That versioning information is written to the file
_Version.h, a file that is NOT preserved in the SCM.
If such a file will be present,
we include it here to utilize the parameters
that are defined therein.
Z_DUAL_ENDSTOPS is a feature to enable the use of 2 endstops for both Z
steppers - Let's call them Z stepper and Z2 stepper.
That way the machine is capable to align the bed during home, since both
Z steppers are homed.
There is also an implementation of M666 (software endstops adjustment)
to this feature.
After Z homing, this adjustment is applied to just one of the steppers
in order to align the bed.
One just need to home the Z axis and measure the distance difference
between both Z axis and apply the math: Z adjust = Z - Z2.
If the Z stepper axis is closer to the bed, the measure Z > Z2 (yes, it
is.. think about it) and the Z adjust would be positive.
Play a little bit with small adjustments (0.5mm) and check the
behaviour.
The M119 (endstops report) will start reporting the Z2 Endstop as well.