Z Probe inverting not present in example configs, causes error
The line const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to
invert the logic of the endstop is in the main configuration.h but
wasn't present in the example configuration.h's. Causes a compiling
error with Z Probe enabled. Just added it to all the configs. :)
Moved the definitions of the LCD_STR_* to Conditionals.h
to avoid errors in Marlin_main.cpp. #1860
In the include tree of Marlin_main.cpp the decision between the display types is not made.
To include the right LCD_STR_* ether 'dogm_lcd_implementation.h' or 'ultralcd_implementation_hitachi_HD44780.h' with all their code.
A 'dogm_lcd_implementation.h.h' would be a curiosity.
So i moved both of the definition blocks to conditionals.h
On the long term it could make sense to use the same numbering for the u8glib and the hitachi symbols.
Because we now can use utf8 with up to 3 bytes per symbol,
lcd_status_message[] must be 3*LCD_WIDTH wide.
Filling up the message, or cutting to length, are fixed to.
Fix for #1832 about at the end.
Splash screen was shown with every display init.
That means every time the menus where entered.
Note the 2 in the initialisation.
The buffer is already written in two steps a 512 byte.
Without the 2 only the upper half is shown.
In 'if (encoderPastThreshold || LCD_CLICKED)' lcdDrawUpdate was not set.
'lcd_status_update_delay'-loop was not effective in function
lcd_status_screen().
The loop prevented the update of the status screen but not the displays
update.
Shifted the loop into lcd_update().