Scott Lahteine
8b3d63c423
Unify Delta XYZ homing rates
As noted in #130 allen key probe stow rate is based on homing rates,
but homing rates were left out of most delta configs. This unifies the
XYZ homing rates and applies the unified rates to allen key movements.
пре 9 година
Scott Lahteine
7c72b57313
Unify manual feedrate and Fix LCD MANUAL_FEEDRATE (PR#128)
As noted by @o-lampe at https://github.com/MarlinFirmware/MarlinDev/issues/114#issuecomment -136757614 the `MANUAL_FEEDRATE` for Delta Z should be the same as XY.
пре 9 година
Scott Lahteine
f690b82343
Remove extra MAX_FREQ_TIME define (PR#148)
пре 9 година
fmalpartida
868dbbac6a
Updated README to rearrange logo to avoid being crossed out by title.
Added my name following naming convention.
пре 9 година
Richard Wackerbarth
8e4fa08a20
Merge Dual Y&Z towers (PR#108 & PR#147)
пре 9 година
Scott Lahteine
a4c78ae786
Add E1 pins to SENSITIVE_PINS for Dual Y or Dual Z
пре 9 година
Scott Lahteine
a39fadf876
Update kossel-pro example config (again?)
пре 9 година
Scott Lahteine
34e0a8d848
Move Y2 and Z2 pins defines to pins.h
пре 9 година
Scott Lahteine
28599c51c7
Wrap Dual Y options in a conditional
пре 9 година
Scott Lahteine
11a065c0ca
Remove Z2 pins overrides from Configuration_adv.h
пре 9 година
Scott Lahteine
f7f6b5faae
Fix lcd_move_e compile error (PR#143)
Fix a compile error introduced in #98
пре 9 година
Richard Wackerbarth
fe0cbd40fe
Default to SD Card Disabled (PR#139)
пре 9 година
Scott Lahteine
2b30e8ac99
Conditionals for ULTIPANEL without SDSUPPORT
пре 9 година
Scott Lahteine
7c7a4051fe
Disable SDSUPPORT by default
As noted in #133 you can’t disable `SDSUPPORT` with `MAKRPANEL`,
`PANEL_ONE`, `MINIPANEL`, or `ULTIPANEL`. This patch makes it possible
to disable `SDSUPPORT` on these controllers and then disables it by
default.
Users of these controllers will now need to enable `SDSUPPORT` in their
configurations as others currently do.
пре 9 година
Eric Kuzmenko
b23d765991
Added Extrude From Multiple Extruders from LCD feature
пре 9 година
Scott Lahteine
fe8816214f
GPLv2 LICENSE
пре 9 година
fmalpartida
c3c4d50a99
Refreshed logo for release 1.1
пре 9 година
Christian Lefrançois
8347a9d6e4
Fix HOMING_BUMP_DIVISOR for deltas configuration
* Re-bump speed divisor should be the same for delta printer.
пре 9 година
Scott Lahteine
703df2cb6c
Fix error message for probe region sanity check
пре 9 година
Shane Francis
4c8330c15c
Trim Adjustments for Delta Configurations
пре 9 година
Roxy-3DPrintBoard
93a512cf97
Add Roxy-3DPrintBoard to dev team
пре 9 година
Scott Lahteine
962120d1d2
Fix spacing in some conditional blocks
пре 9 година
Richard Wackerbarth
109628a77e
Merge tag debug_G29 (PR#54)
пре 9 година
Richard Wackerbarth
20b4772155
Create DEBUG_LEVELING_FEATURE
пре 9 година
Scott Lahteine
194f98ff95
Debug messages for homing and leveling
пре 9 година
Richard Wackerbarth
6292d9e815
Rename ENABLE_AUTO_BED_LEVELING
With the introduction of the #if ENABLED(…)
reads better than
пре 9 година
Richard Marko
91fd66ffba
add Lulzbot TAZ4 example configuration (PR#104)
пре 9 година
Wurstnase
7a275773ee
remove colon in utf_mapper.h (PR#106)
пре 9 година
Chris Bruner
6b4b6fa315
update for newest version of U8glib_Arduino
пре 9 година
Christian Lefrançois
9897a9147c
Update ABL comments (PR#95)
* Updates the auto bed leveling comments ONLY.
* Renames "Z probe" word usage in //comments and #errors properly.
пре 9 година
Christian Lefrançois
a7822e3ff7
Some renaming of Z_PROBE to Z_MIN_PROBE (PR#91)
* Fix a couple of renames omission and macro expansion errors.
пре 9 година
Richard Wackerbarth
4939c642b4
Merge Suppress some compiler warnings (PR#70)
пре 9 година
Richard Wackerbarth
ad90e851b3
Use a small unsigned integer type
пре 9 година
Richard Wackerbarth
29b456ae07
Suppress some compiler warnings
пре 9 година
Scott Lahteine
23d742bf06
Don't free the stack array plane_equation_coefficients (PR#83)
пре 9 година
Scott Lahteine
e3b1e08777
Patch G30 to use raise_z_for_servo (PR#73)
пре 9 година
Richard Wackerbarth
c2f695c84e
Merge Save a few bytes (PR#79)
пре 9 година
Scott Lahteine
a1eb90d5c0
Save another 30 bytes in gcode_SET_Z_PROBE_OFFSET
пре 9 година
Scott Lahteine
91122277f4
Reduce gcode_SET_Z_PROBE_OFFSET by 88 bytes
пре 9 година
Richard Wackerbarth
9531b154ea
Merge Zig-Zag Endpoint (PR#65)
пре 9 година
AnHardt
5707a2c3d5
indexindexIntoAB is only vald for !DELTA
пре 9 година
AnHardt
d8860f9ad9
Alway end at the same point
Always end at [RIGHT_PROBE_BED_POSITION, BACK_PROBE_BED_POSITION]
Regardles the evennes of auto_bed_leveling_grid_points.
пре 9 година
AnHardt
4ca8f4a9a7
Always zigzag
Use the shortest way between probing-points.
пре 9 година
AnHardt
3d23424121
Add array indexIntoAB[xx][yy]
and use it.
пре 9 година
AnHardt
e2d69f66b2
Make Z_PROBE a Z_MIN_PROBE (PR#65)
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.
Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX check for the probe in update_endstops().
Using an delta related idea of @clefranc from #61 ,
extended to the general change for all setups.
Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc 's delta.
пре 9 година
AnHardt
8d23c4230e
Add a Travis test for Z_DUAL_STEPPER_DRIVERS and Z_DUAL_ENDSTOPS (PR#68)
пре 9 година
AnHardt
6a6e863a47
Resolve #2581 by adding a missed ';' (PR#67)
пре 9 година
RicardoGA
e09ff79635
Update pins_RAMPS_13.h (PR#64)
Now all ramps configuration can enable Filament sensor not only EEB
пре 9 година
Fourmi
e6aed7bb4e
Update thermistortables for Hisens Thermistor (PR#2588)
пре 9 година
Richard Wackerbarth
9d8cc24abf
Continue from the line following the M999 (PR#60)
If the printer is going to accept the M999,
then it should continue from that line number.
пре 9 година