123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147 |
- /**
- * Marlin 3D Printer Firmware
- * Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
- *
- * Based on Sprinter and grbl.
- * Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
- *
- * This program is free software: you can redistribute it and/or modify
- * it under the terms of the GNU General Public License as published by
- * the Free Software Foundation, either version 3 of the License, or
- * (at your option) any later version.
- *
- * This program is distributed in the hope that it will be useful,
- * but WITHOUT ANY WARRANTY; without even the implied warranty of
- * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
- * GNU General Public License for more details.
- *
- * You should have received a copy of the GNU General Public License
- * along with this program. If not, see <https://www.gnu.org/licenses/>.
- *
- */
- #pragma once
-
- #include "../inc/MarlinConfig.h"
-
- enum TempSensorID : uint8_t {
- TSI_PROBE,
- TSI_BED,
- #if ENABLED(USE_TEMP_EXT_COMPENSATION)
- TSI_EXT,
- #endif
- TSI_COUNT
- };
-
- typedef struct {
- uint8_t measurements; // Max. number of measurements to be stored (35 - 80°C)
- float temp_res, // Resolution in °C between measurements
- start_temp, // Base measurement; z-offset == 0
- end_temp;
- } temp_calib_t;
-
- /**
- * Probe temperature compensation implementation.
- * Z-probes like the P.I.N.D.A V2 allow for compensation of
- * measurement errors/shifts due to changed temperature.
- */
-
- // Probe temperature calibration constants
- #ifndef PTC_SAMPLE_COUNT
- #define PTC_SAMPLE_COUNT 10U
- #endif
- #ifndef PTC_SAMPLE_RES
- #define PTC_SAMPLE_RES 5.0f
- #endif
- #ifndef PTC_SAMPLE_START
- #define PTC_SAMPLE_START 30.0f
- #endif
- #define PTC_SAMPLE_END ((PTC_SAMPLE_START) + (PTC_SAMPLE_COUNT) * (PTC_SAMPLE_RES))
-
- // Bed temperature calibration constants
- #ifndef BTC_PROBE_TEMP
- #define BTC_PROBE_TEMP 30.0f
- #endif
- #ifndef BTC_SAMPLE_COUNT
- #define BTC_SAMPLE_COUNT 10U
- #endif
- #ifndef BTC_SAMPLE_STEP
- #define BTC_SAMPLE_RES 5.0f
- #endif
- #ifndef BTC_SAMPLE_START
- #define BTC_SAMPLE_START 60.0f
- #endif
- #define BTC_SAMPLE_END ((BTC_SAMPLE_START) + (BTC_SAMPLE_COUNT) * (BTC_SAMPLE_RES))
-
- #ifndef PTC_PROBE_HEATING_OFFSET
- #define PTC_PROBE_HEATING_OFFSET 0.5f
- #endif
-
- #ifndef PTC_PROBE_RAISE
- #define PTC_PROBE_RAISE 10.0f
- #endif
-
- static constexpr temp_calib_t cali_info_init[TSI_COUNT] = {
- { PTC_SAMPLE_COUNT, PTC_SAMPLE_RES, PTC_SAMPLE_START, PTC_SAMPLE_END }, // Probe
- { BTC_SAMPLE_COUNT, BTC_SAMPLE_RES, BTC_SAMPLE_START, BTC_SAMPLE_END }, // Bed
- #if ENABLED(USE_TEMP_EXT_COMPENSATION)
- { 20, 5, 180, 180 + 5 * 20 } // Extruder
- #endif
- };
-
- class ProbeTempComp {
- public:
-
- static const temp_calib_t cali_info[TSI_COUNT];
-
- // Where to park nozzle to wait for probe cooldown
- static constexpr xyz_pos_t park_point = PTC_PARK_POS;
-
- // XY coordinates of nozzle for probing the bed
- static constexpr xy_pos_t measure_point = PTC_PROBE_POS; // Coordinates to probe
- //measure_point = { 12.0f, 7.3f }; // Coordinates for the MK52 magnetic heatbed
-
- static constexpr int probe_calib_bed_temp = BED_MAX_TARGET, // Bed temperature while calibrating probe
- bed_calib_probe_temp = BTC_PROBE_TEMP; // Probe temperature while calibrating bed
-
- static int16_t *sensor_z_offsets[TSI_COUNT],
- z_offsets_probe[cali_info_init[TSI_PROBE].measurements], // (µm)
- z_offsets_bed[cali_info_init[TSI_BED].measurements]; // (µm)
-
- #if ENABLED(USE_TEMP_EXT_COMPENSATION)
- static int16_t z_offsets_ext[cali_info_init[TSI_EXT].measurements]; // (µm)
- #endif
-
- static inline void reset_index() { calib_idx = 0; };
- static inline uint8_t get_index() { return calib_idx; }
- static void clear_offsets(const TempSensorID tsi);
- static inline void clear_all_offsets() {
- clear_offsets(TSI_BED);
- clear_offsets(TSI_PROBE);
- TERN_(USE_TEMP_EXT_COMPENSATION, clear_offsets(TSI_EXT));
- }
- static bool set_offset(const TempSensorID tsi, const uint8_t idx, const int16_t offset);
- static void print_offsets();
- static void prepare_new_calibration(const float &init_meas_z);
- static void push_back_new_measurement(const TempSensorID tsi, const float &meas_z);
- static bool finish_calibration(const TempSensorID tsi);
- static void compensate_measurement(const TempSensorID tsi, const float &temp, float &meas_z);
-
- private:
- static uint8_t calib_idx;
-
- /**
- * Base value. Temperature compensation values will be deltas
- * to this value, set at first probe.
- */
- static float init_measurement;
-
- static float get_offset_for_temperature(const TempSensorID tsi, const float &temp);
-
- /**
- * Fit a linear function in measured temperature offsets
- * to allow generating values of higher temperatures.
- */
- static bool linear_regression(const TempSensorID tsi, float &k, float &d);
- };
-
- extern ProbeTempComp temp_comp;
|