123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311 |
- /**
- * SanityCheck.h
- *
- * Test configuration values for errors at compile-time.
- */
- #ifndef SANITYCHECK_H
- #define SANITYCHECK_H
-
- /**
- * Dual Stepper Drivers
- */
- #if defined(Z_DUAL_STEPPER_DRIVERS) && defined(Y_DUAL_STEPPER_DRIVERS)
- #error You cannot have dual stepper drivers for both Y and Z.
- #endif
-
- /**
- * Progress Bar
- */
- #ifdef LCD_PROGRESS_BAR
- #ifndef SDSUPPORT
- #error LCD_PROGRESS_BAR requires SDSUPPORT.
- #endif
- #ifdef DOGLCD
- #error LCD_PROGRESS_BAR does not apply to graphical displays.
- #endif
- #ifdef FILAMENT_LCD_DISPLAY
- #error LCD_PROGRESS_BAR and FILAMENT_LCD_DISPLAY are not fully compatible. Comment out this line to use both.
- #endif
- #endif
-
- /**
- * Babystepping
- */
- #ifdef BABYSTEPPING
- #ifdef COREXY
- #error BABYSTEPPING not implemented for COREXY yet.
- #endif
- #ifdef SCARA
- #error BABYSTEPPING is not implemented for SCARA yet.
- #endif
- #if defined(DELTA) && defined(BABYSTEP_XY)
- #error BABYSTEPPING only implemented for Z axis on deltabots.
- #endif
- #endif
-
- /**
- * Filament Change with Extruder Runout Prevention
- */
- #if defined(FILAMENTCHANGEENABLE) && defined(EXTRUDER_RUNOUT_PREVENT)
- #error EXTRUDER_RUNOUT_PREVENT currently incompatible with FILAMENTCHANGE.
- #endif
-
- /**
- * Options only for EXTRUDERS == 1
- */
- #if EXTRUDERS > 1
-
- #if EXTRUDERS > 4
- #error The maximum number of EXTRUDERS in Marlin is 4.
- #endif
-
- #ifdef TEMP_SENSOR_1_AS_REDUNDANT
- #error EXTRUDERS must be 1 with TEMP_SENSOR_1_AS_REDUNDANT.
- #endif
-
- #ifdef HEATERS_PARALLEL
- #error EXTRUDERS must be 1 with HEATERS_PARALLEL.
- #endif
-
- #ifdef Y_DUAL_STEPPER_DRIVERS
- #error EXTRUDERS must be 1 with Y_DUAL_STEPPER_DRIVERS.
- #endif
-
- #ifdef Z_DUAL_STEPPER_DRIVERS
- #error EXTRUDERS must be 1 with Z_DUAL_STEPPER_DRIVERS.
- #endif
-
- #endif // EXTRUDERS > 1
-
- /**
- * Limited number of servos
- */
- #if NUM_SERVOS > 4
- #error The maximum number of SERVOS in Marlin is 4.
- #endif
-
- /**
- * Servo deactivation depends on servo endstops
- */
- #if defined(DEACTIVATE_SERVOS_AFTER_MOVE) && !defined(SERVO_ENDSTOPS)
- #error SERVO_ENDSTOPS is required for DEACTIVATE_SERVOS_AFTER_MOVE.
- #endif
-
- /**
- * Required LCD language
- */
- #if !defined(DOGLCD) && defined(ULTRA_LCD) && !defined(DISPLAY_CHARSET_HD44780_JAPAN) && !defined(DISPLAY_CHARSET_HD44780_WESTERN)&& !defined(DISPLAY_CHARSET_HD44780_CYRILLIC)
- #error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
- #endif
-
- /**
- * Mesh Bed Leveling
- */
- #ifdef MESH_BED_LEVELING
- #ifdef DELTA
- #error MESH_BED_LEVELING does not yet support DELTA printers.
- #endif
- #ifdef ENABLE_AUTO_BED_LEVELING
- #error Select ENABLE_AUTO_BED_LEVELING or MESH_BED_LEVELING, not both.
- #endif
- #if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
- #error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8.
- #endif
- #endif
-
- /**
- * Auto Bed Leveling
- */
- #ifdef ENABLE_AUTO_BED_LEVELING
-
- /**
- * Require a Z Min pin
- */
- #if Z_MIN_PIN == -1
- #if Z_PROBE_PIN == -1 || (!defined(Z_PROBE_ENDSTOP) || defined(DISABLE_Z_PROBE_ENDSTOP)) // It's possible for someone to set a pin for the Z Probe, but not enable it.
- #ifdef Z_PROBE_REPEATABILITY_TEST
- #error You must have a Z_MIN or Z_PROBE endstop to enable Z_PROBE_REPEATABILITY_TEST.
- #else
- #error ENABLE_AUTO_BED_LEVELING requires a Z_MIN or Z_PROBE endstop. Z_MIN_PIN or Z_PROBE_PIN must point to a valid hardware pin.
- #endif
- #endif
- #endif
-
- /**
- * Require a Z Probe Pin if Z_PROBE_ENDSTOP is enabled.
- */
- #if defined(Z_PROBE_ENDSTOP)
- #ifndef Z_PROBE_PIN
- #error You must have a Z_PROBE_PIN defined in your pins_XXXX.h file if you enable Z_PROBE_ENDSTOP.
- #endif
- #if Z_PROBE_PIN == -1
- #error You must set Z_PROBE_PIN to a valid pin if you enable Z_PROBE_ENDSTOP.
- #endif
- // Forcing Servo definitions can break some hall effect sensor setups. Leaving these here for further comment.
- // #ifndef NUM_SERVOS
- // #error You must have NUM_SERVOS defined and there must be at least 1 configured to use Z_PROBE_ENDSTOP.
- // #endif
- // #if defined(NUM_SERVOS) && NUM_SERVOS < 1
- // #error You must have at least 1 servo defined for NUM_SERVOS to use Z_PROBE_ENDSTOP.
- // #endif
- // #ifndef SERVO_ENDSTOPS
- // #error You must have SERVO_ENDSTOPS defined and have the Z index set to at least 0 or above to use Z_PROBE_ENDSTOP.
- // #endif
- // #ifndef SERVO_ENDSTOP_ANGLES
- // #error You must have SERVO_ENDSTOP_ANGLES defined for Z Extend and Retract to use Z_PROBE_ENDSTOP.
- // #endif
- #endif
- /**
- * Check if Probe_Offset * Grid Points is greater than Probing Range
- */
- #ifdef AUTO_BED_LEVELING_GRID
- #ifndef DELTA_PROBABLE_RADIUS
- // Be sure points are in the right order
- #if LEFT_PROBE_BED_POSITION > RIGHT_PROBE_BED_POSITION
- #error LEFT_PROBE_BED_POSITION must be less than RIGHT_PROBE_BED_POSITION.
- #elif FRONT_PROBE_BED_POSITION > BACK_PROBE_BED_POSITION
- #error BACK_PROBE_BED_POSITION must be less than FRONT_PROBE_BED_POSITION.
- #endif
- // Make sure probing points are reachable
- #if LEFT_PROBE_BED_POSITION < MIN_PROBE_X
- #error "The given LEFT_PROBE_BED_POSITION can't be reached by the probe."
- #elif RIGHT_PROBE_BED_POSITION > MAX_PROBE_X
- #error "The given RIGHT_PROBE_BED_POSITION can't be reached by the probe."
- #elif FRONT_PROBE_BED_POSITION < MIN_PROBE_Y
- #error "The given FRONT_PROBE_BED_POSITION can't be reached by the probe."
- #elif BACK_PROBE_BED_POSITION > MAX_PROBE_Y
- #error "The given BACK_PROBE_BED_POSITION can't be reached by the probe."
- #endif
- #endif
- #else // !AUTO_BED_LEVELING_GRID
-
- // Check the triangulation points
- #if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
- #error "The given ABL_PROBE_PT_1_X can't be reached by the probe."
- #elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
- #error "The given ABL_PROBE_PT_2_X can't be reached by the probe."
- #elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
- #error "The given ABL_PROBE_PT_3_X can't be reached by the probe."
- #elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
- #error "The given ABL_PROBE_PT_1_Y can't be reached by the probe."
- #elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
- #error "The given ABL_PROBE_PT_2_Y can't be reached by the probe."
- #elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
- #error "The given ABL_PROBE_PT_3_Y can't be reached by the probe."
- #endif
-
- #endif // !AUTO_BED_LEVELING_GRID
-
- #endif // ENABLE_AUTO_BED_LEVELING
-
- /**
- * ULTIPANEL encoder
- */
- #if defined(ULTIPANEL) && !defined(NEWPANEL) && !defined(SR_LCD_2W_NL) && !defined(SHIFT_CLK)
- #error ULTIPANEL requires some kind of encoder.
- #endif
-
- /**
- * Delta has limited bed leveling options
- */
- #ifdef DELTA
-
- #ifdef ENABLE_AUTO_BED_LEVELING
-
- #ifndef AUTO_BED_LEVELING_GRID
- #error Only AUTO_BED_LEVELING_GRID is supported with DELTA.
- #endif
-
- #ifdef Z_PROBE_SLED
- #error You cannot use Z_PROBE_SLED with DELTA.
- #endif
-
- #ifdef Z_PROBE_REPEATABILITY_TEST
- #error Z_PROBE_REPEATABILITY_TEST is not supported with DELTA yet.
- #endif
-
- #endif
-
- #endif
-
- /**
- * Allen Key Z Probe requires Auto Bed Leveling grid and Delta
- */
- #if defined(Z_PROBE_ALLEN_KEY) && !(defined(AUTO_BED_LEVELING_GRID) && defined(DELTA))
- #error Invalid use of Z_PROBE_ALLEN_KEY.
- #endif
-
- /**
- * Dual X Carriage requirements
- */
- #ifdef DUAL_X_CARRIAGE
- #if EXTRUDERS == 1 || defined(COREXY) \
- || !HAS_X2_ENABLE || !HAS_X2_STEP || !HAS_X2_DIR \
- || !defined(X2_HOME_POS) || !defined(X2_MIN_POS) || !defined(X2_MAX_POS) \
- || !HAS_X_MAX
- #error Missing or invalid definitions for DUAL_X_CARRIAGE mode.
- #endif
- #if X_HOME_DIR != -1 || X2_HOME_DIR != 1
- #error Please use canonical x-carriage assignment.
- #endif
- #endif // DUAL_X_CARRIAGE
-
- /**
- * Make sure auto fan pins don't conflict with the fan pin
- */
- #if HAS_AUTO_FAN && HAS_FAN
- #if EXTRUDER_0_AUTO_FAN_PIN == FAN_PIN
- #error You cannot set EXTRUDER_0_AUTO_FAN_PIN equal to FAN_PIN.
- #elif EXTRUDER_1_AUTO_FAN_PIN == FAN_PIN
- #error You cannot set EXTRUDER_1_AUTO_FAN_PIN equal to FAN_PIN.
- #elif EXTRUDER_2_AUTO_FAN_PIN == FAN_PIN
- #error You cannot set EXTRUDER_2_AUTO_FAN_PIN equal to FAN_PIN.
- #elif EXTRUDER_3_AUTO_FAN_PIN == FAN_PIN
- #error You cannot set EXTRUDER_3_AUTO_FAN_PIN equal to FAN_PIN.
- #endif
- #endif
-
- #if HAS_FAN && CONTROLLERFAN_PIN == FAN_PIN
- #error You cannot set CONTROLLERFAN_PIN equal to FAN_PIN.
- #endif
-
- /**
- * Test required HEATER defines
- */
- #if EXTRUDERS > 3
- #if !HAS_HEATER_3
- #error HEATER_3_PIN not defined for this board.
- #endif
- #elif EXTRUDERS > 2
- #if !HAS_HEATER_2
- #error HEATER_2_PIN not defined for this board.
- #endif
- #elif EXTRUDERS > 1 || defined(HEATERS_PARALLEL)
- #if !HAS_HEATER_1
- #error HEATER_1_PIN not defined for this board.
- #endif
- #endif
- #if !HAS_HEATER_0
- #error HEATER_0_PIN not defined for this board.
- #endif
-
- /**
- * Warnings for old configurations
- */
- #ifdef X_HOME_RETRACT_MM
- #error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM.
- #endif
-
- #if WATCH_TEMP_PERIOD > 500
- #error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds.
- #endif
-
- #if !defined(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
- #error Thermal Runaway Protection for hotends must now be enabled with THERMAL_PROTECTION_HOTENDS.
- #endif
-
- #if !defined(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
- #error Thermal Runaway Protection for the bed must now be enabled with THERMAL_PROTECTION_BED.
- #endif
-
- #endif //SANITYCHECK_H
|