Selaa lähdekoodia

Adjust for timing shift on Max7219 displays on AVR's

Something has shifted.   The previous timing delays on the Max7219 debug displays is too tight without this correction.
I suspect something has been optimized and roughly 50ns of needed setup and hold time has disappeared.
This corrects the issue and the display results are clean again.
Roxy-3D 4 vuotta sitten
vanhempi
commit
5d515c3a2f
No account linked to committer's email address
1 muutettua tiedostoa jossa 1 lisäystä ja 1 poistoa
  1. 1
    1
      Marlin/src/feature/max7219.cpp

+ 1
- 1
Marlin/src/feature/max7219.cpp Näytä tiedosto

@@ -121,7 +121,7 @@ uint8_t Max7219::suspended; // = 0;
121 121
   #define CRITICAL_SECTION_START() NOOP
122 122
   #define CRITICAL_SECTION_END()   NOOP
123 123
 #else
124
-  #define SIG_DELAY() DELAY_NS(188) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
124
+  #define SIG_DELAY() DELAY_NS(250) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
125 125
 #endif