Sfoglia il codice sorgente

Adjust for timing shift on Max7219 displays on AVR's

Something has shifted.   The previous timing delays on the Max7219 debug displays is too tight without this correction.
I suspect something has been optimized and roughly 50ns of needed setup and hold time has disappeared.
This corrects the issue and the display results are clean again.
Roxy-3D 4 anni fa
parent
commit
5d515c3a2f
Nessun account collegato all'indirizzo email del committer
1 ha cambiato i file con 1 aggiunte e 1 eliminazioni
  1. 1
    1
      Marlin/src/feature/max7219.cpp

+ 1
- 1
Marlin/src/feature/max7219.cpp Vedi File

@@ -121,7 +121,7 @@ uint8_t Max7219::suspended; // = 0;
121 121
   #define CRITICAL_SECTION_START() NOOP
122 122
   #define CRITICAL_SECTION_END()   NOOP
123 123
 #else
124
-  #define SIG_DELAY() DELAY_NS(188) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
124
+  #define SIG_DELAY() DELAY_NS(250) // Delay for 0.1875µs (16MHz AVR) or 0.15µs (20MHz AVR)
125 125
 #endif
126 126
 
127 127
 void Max7219::error(const char * const func, const int32_t v1, const int32_t v2/*=-1*/) {

Loading…
Annulla