Procházet zdrojové kódy

tweak height, homing and bed temperature control

Thomas Buck před 4 roky
rodič
revize
824ae4a0fc
2 změnil soubory, kde provedl 5 přidání a 5 odebrání
  1. 2
    2
      Marlin/Configuration.h
  2. 3
    3
      Marlin/Configuration_adv.h

+ 2
- 2
Marlin/Configuration.h Zobrazit soubor

@@ -1132,7 +1132,7 @@
1132 1132
 #define Z_MIN_POS 0
1133 1133
 #define X_MAX_POS X_BED_SIZE
1134 1134
 #define Y_MAX_POS Y_BED_SIZE
1135
-#define Z_MAX_POS 165
1135
+#define Z_MAX_POS 200
1136 1136
 
1137 1137
 /**
1138 1138
  * Software Endstops
@@ -1386,7 +1386,7 @@
1386 1386
 // - Move the Z probe (or nozzle) to a defined XY point before Z Homing.
1387 1387
 // - Prevent Z homing when the Z probe is outside bed area.
1388 1388
 //
1389
-//#define Z_SAFE_HOMING
1389
+#define Z_SAFE_HOMING
1390 1390
 
1391 1391
 #if ENABLED(Z_SAFE_HOMING)
1392 1392
   #define Z_SAFE_HOMING_X_POINT X_CENTER  // X point for Z homing

+ 3
- 3
Marlin/Configuration_adv.h Zobrazit soubor

@@ -128,7 +128,7 @@
128 128
 // Heated Bed Bang-Bang options
129 129
 //
130 130
 #if DISABLED(PIDTEMPBED)
131
-  #define BED_CHECK_INTERVAL 2000   // (ms) Interval between checks in bang-bang control
131
+  #define BED_CHECK_INTERVAL 1000   // (ms) Interval between checks in bang-bang control
132 132
   #if ENABLED(BED_LIMIT_SWITCHING)
133 133
     #define BED_HYSTERESIS 2        // (°C) Only set the relevant heater state when ABS(T-target) > BED_HYSTERESIS
134 134
   #endif
@@ -214,8 +214,8 @@
214 214
  * Thermal Protection parameters for the bed are just as above for hotends.
215 215
  */
216 216
 #if ENABLED(THERMAL_PROTECTION_BED)
217
-  #define THERMAL_PROTECTION_BED_PERIOD        20 // Seconds
218
-  #define THERMAL_PROTECTION_BED_HYSTERESIS     2 // Degrees Celsius
217
+  #define THERMAL_PROTECTION_BED_PERIOD        60 // Seconds
218
+  #define THERMAL_PROTECTION_BED_HYSTERESIS     5 // Degrees Celsius
219 219
 
220 220
   /**
221 221
    * As described above, except for the bed (M140/M190/M303).

Loading…
Zrušit