@@ -128,7 +128,7 @@
|
128
|
128
|
// Heated Bed Bang-Bang options
|
129
|
129
|
//
|
130
|
130
|
#if DISABLED(PIDTEMPBED)
|
131
|
|
- #define BED_CHECK_INTERVAL 2000 // (ms) Interval between checks in bang-bang control
|
|
131
|
+ #define BED_CHECK_INTERVAL 1000 // (ms) Interval between checks in bang-bang control
|
132
|
132
|
#if ENABLED(BED_LIMIT_SWITCHING)
|
133
|
133
|
#define BED_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > BED_HYSTERESIS
|
134
|
134
|
#endif
|
|
@@ -214,8 +214,8 @@
|
214
|
214
|
* Thermal Protection parameters for the bed are just as above for hotends.
|
215
|
215
|
*/
|
216
|
216
|
#if ENABLED(THERMAL_PROTECTION_BED)
|
217
|
|
- #define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
218
|
|
- #define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
|
217
|
+ #define THERMAL_PROTECTION_BED_PERIOD 60 // Seconds
|
|
218
|
+ #define THERMAL_PROTECTION_BED_HYSTERESIS 5 // Degrees Celsius
|
219
|
219
|
|
220
|
220
|
/**
|
221
|
221
|
* As described above, except for the bed (M140/M190/M303).
|