AnHardt
b7e9ba7591
Back to 1.0.3 dev - for now
9 vuotta sitten
AnHardt
b1404a0743
fix thermal protection state machine target temp. V2
If the target temperature is changed then it would always stay in the reset state.
Thanks to @tonokip.
Replaces #2119
9 vuotta sitten
AnHardt
17b0ec84ed
Fix out_of_range_error()
For sprintf_P() the first parameter has to be a `char*` not `const char*`.
9 vuotta sitten
wurstnase
e7e964432b
consistency name for multiplier
replace extruder_multiply with extruder_multiplier
like feedrate_multiplier or volumetric_multiplier
9 vuotta sitten
AnHardt
0d9d21d15f
Add a semicolon to make Z_DUAL_STEPPER_DRIVERS compile again.
9 vuotta sitten
MagoKimbra
881146bc22
Fix problem Width Cura
9 vuotta sitten
Alexey Shvetsov
a8670b66a7
Update ru translation
Signed-off-by: Alexey Shvetsov <alexxy@gentoo.org >
9 vuotta sitten
fmalpartida
93da52d011
Added support for OLED SSD1306 I2C based LCDs.
9 vuotta sitten
wurstnase
0f3f7d6835
clean up double endstops
9 vuotta sitten
Scott Lahteine
be5236e839
Reduce setTargetedHotend by removing the switch
9 vuotta sitten
Scott Lahteine
06f401e7e5
Redo "invalid extruder" to save 264 bytes
- Use `setTargetedHotend` in `M200`, as with other commands that use
`T` for the extruder
- Synthesize the "invalid extruder" message, obviating several long
strings
9 vuotta sitten
Scott Lahteine
9beed830eb
Drop commented code_is_good lines
9 vuotta sitten
Scott Lahteine
068d4a1eb2
Ignore unknown commands if they start with G, M, or T
9 vuotta sitten
Scott Lahteine
0564625757
Update M33 for new gcode parser
9 vuotta sitten
AnHardt
f18f689c01
Replace MSG_F? with MSG_N?
To avoid double definitions.
I prefer to read N for Number not for Nozzle.
9 vuotta sitten
AnHardt
af7e3f5076
Print active extruder with M105 for MAX6675
Was omitted when T0 is a MAX6675.
9 vuotta sitten
Jonathan Bastien-Filiatrault
d46d9d998e
Add maximum bed integral term in example configurations.
9 vuotta sitten
Jonathan Bastien-Filiatrault
e86f2342c0
Separate the maximum integral power for the bed from PID_INTEGRAL_DRIVE_MAX / PID_MAX.
My PID_INTEGRAL_DRIVE_MAX was at 96, which was insufficient for my bed
to reach its intended temperature. The head requires a low maximum power since
I run on 24 volts and it has a somewhat low thermal mass.
9 vuotta sitten
AnHardt
f0523b5816
Initialize the display earlier
to have it ready to display errors during (temperature)-setup.
9 vuotta sitten
Scott Lahteine
790c697c19
Fix DEGREES macro
9 vuotta sitten
Scott Lahteine
03d5709b09
M110 is a known command
- The command parser now displays “unknown command” in more cases.
Known commands must be added to the `switch` inside `process_commands`
to suppress the error.
9 vuotta sitten
Scott Lahteine
d76a01194d
Slight size reduction by adding idle()
9 vuotta sitten
Richard Wackerbarth
2deb5a8ac5
Temporary Hack
REVERT THIS CHANGE
In proper use, we want to force the vendor to update this file to reflect distribution parameters
However, until most users have converted to automatic versioning,
we “grant them a pass”
9 vuotta sitten
Richard Wackerbarth
b5743d6927
Use SOURCE_CODE_URL rather than FIRMWARE_URL
9 vuotta sitten
Richard Wackerbarth
5ea139fd79
Revised Versioning mechanism
9 vuotta sitten
AnHardt
da246f5cb1
Activate BED_MINTEMP error.
And call _temp_error() directly for ERR_MAXTEMP_BED to avoid the only one time use of bed_max_temp_error().
Includes #2156 .
9 vuotta sitten
AnHardt
959da98d8e
Call kill() only once when triggered by a temperature error
to avoid stack overflow when called from interrupt.
Some clean up for calls of disable_all_heaters().
'disable_all_heaters()' is called in kill() and again when 'killed' is already set inside _temp_error().
9 vuotta sitten
Scott Lahteine
68f6f149d0
Reduce code size with out_of_range_error function
- Affects code size when automatic bed leveling is enabled
9 vuotta sitten
wurstnase
94120740d8
faster compare
!(~(ab)&0x3) and ab == 0x3 are equal
9 vuotta sitten
Scott Lahteine
b55f8718c3
Indent G90/G91, G92
9 vuotta sitten
Scott Lahteine
b0d520b109
Indent G30, G31/G32
9 vuotta sitten
Scott Lahteine
ffe27a6225
Indent G29
9 vuotta sitten
Scott Lahteine
86083badc2
Indent G4, G10/G11, G28
9 vuotta sitten
Scott Lahteine
47d7a9cb5e
Indent G2/G3
9 vuotta sitten
Scott Lahteine
350f239d84
Indent G0/G1
9 vuotta sitten
Scott Lahteine
672b0c1fd3
Cleanup pins in RAMPS_13_EFB boards
9 vuotta sitten
Scott Lahteine
15a2351675
No need for +1 on initial seen_pointer
9 vuotta sitten
Scott Lahteine
550dd87b2a
Set seen_pointer before calling code_value
9 vuotta sitten
Scott Lahteine
063881b5bd
Fix a couple of doubled semicolons
9 vuotta sitten
AnHardt
0c0ace2a04
Remove start_watching_heater() fom M104 and M109
9 vuotta sitten
Scott Lahteine
00716d0ca0
Small start_watching_heater adjustment
9 vuotta sitten
Scott Lahteine
bde9c70d42
Suppress the line mismatch error after M303
9 vuotta sitten
wurstnase
ff98b8632b
new endstop bits
9 vuotta sitten
AnHardt
9b0fa9c309
Changed dependency of start_watching_heater() in setTargetHotend() to THERMAL_PROTECTION_HOTENDS
9 vuotta sitten
AnHardt
bc0764894a
Shift call of start_watching_heater() into setTargetHotend()
to warrant watching is set or reset.
Make setTargetBed() in _lcd_preheat() dependant of TEMP_SENSOR_BED.
Use disable_all_heaters() in lcd_cooldown() and abort_on_endstop_hit.
9 vuotta sitten
Richard Wackerbarth
b878bc5620
Introducing the Kossel Pro Build Configuration
9 vuotta sitten
Richard Wackerbarth
1d8f61ca8a
AT90USB is defined in pins.h
9 vuotta sitten
Richard Wackerbarth
735bf2d35f
Describe Custom M Code
9 vuotta sitten
Scott Lahteine
f39658c822
M120 and M121 are reversed
9 vuotta sitten
Scott Lahteine
6eb4f90ce7
Also synchronize configurator copies of configs
9 vuotta sitten