- MENU_ITEM causes lcd_quick_feedback to be called, so only those calls
to `lcd_goto_menu` outside of the `MENU_ITEM` macro need to set the
`feedback` flag when calling `lcd_goto_menu`.
Because we now can use utf8 with up to 3 bytes per symbol,
lcd_status_message[] must be 3*LCD_WIDTH wide.
Filling up the message, or cutting to length, are fixed to.
Fix for #1832 about at the end.
In 'if (encoderPastThreshold || LCD_CLICKED)' lcdDrawUpdate was not set.
'lcd_status_update_delay'-loop was not effective in function
lcd_status_screen().
The loop prevented the update of the status screen but not the displays
update.
Shifted the loop into lcd_update().
- Some messages should not expire with `PROGRESS_MSG_EXPIRE`.
- Simplify conditional for progress bar with sanity checks.
- Rename `messageTick` to `expireStatusMillis` and make it the expire
time.
Report changes from previous PR from old code base including :
I've updated the minimum values from the LCD.
It has been a while that i want to at least fix this.
I have an inductive probe and often i need to set my zOffset to something lower than 0.5.
With the current implementation, the default LCD value is set to 0.5 for some reason.
On my case i need to be able to set it down to 0.0 as my inductive probe can be lower than 0.5.
Before with the LCD we couldn't change this value below 0.5. We had to flash the firmware every time which was painful.
Now we are able to change this value down to 0.0 if needed.
I've also changed the minimum value for Z min acceleration.
In the default configuration it's set to 25 but on the LCD the minimum was 100 which is not coherent.
I've changes the minimum to 10. On this axis, depending on the mechanics/motor drivers we might require very low acceleration, so i guess 10 is somehow realistic.
- Add `Conditionals.h` with calculated configuration values
- Add `SanityCheck.h` with checks for configuration errors
- Remove equivalent code from all configurations
- Move error checks from some sources to `SanityCheck.h` also
- Fix initialization of count_direction in stepper.cpp
When one hit "Stop Print" option in LCD menu, the command buffer was not
cleared. The printer keep moving until the buffer has been emptied.
Actually I could not clear the command buffer as well.. I don't know
why, it doesnt work as expected.
I need to implement a routine inside Stepper ISR to handle such
situation.
While bunting an other bug I stumbled across:
ultralcd.cpp:1250: warning: comparison between signed and unsigned
integer expressions
Changed to the type of lcd_next_update_millis.
- Add BIT and TEST macros
- Add _APPLY_ macros to stepper.cpp to help with consolidation
- Consolidate code in stepper.cpp using macros
- Apply standards in stepper.cpp
- Use >= 0 instead of > -1 as a better semantic
- Replace DUAL_Y_CARRIAGE with Y_DUAL_STEPPER_DRIVERS
Add Travel Acceleration and change the M204 options
Added option to set Travel Acceleration (non printing moves).
The M204 options was a non sense (S for printing moves and T for retract
moves).
It has been changed to:
P = Printing moves
R = Retract only (no X, Y, Z) moves
T = Travel (non
printing) moves
I will add this info o G-Code wiki in reprap.org. I also advise to put
this info in Marlin next version changelog.