Am I the only one who always need to change the thermistortable.h to add
a dummy table??
Ok, it is done. Just set the thermistor to 999 and it will always read
25C. Great for Testing or Development purposes.
Additional fixes to temperature.cpp and found another missing line
Looks like INVERT_E3_DIR was missing in the configuration.h also as I
did a test compile with 4 extruders and Azteeg X3 Pro defined. So I also
added those lines too. Additional formatting to make the comments line
up better in that section.
I've insert the define and pointer entries for the Viki 2 and miniViki
from Panucatt in all of the example configs and main config. With these
additions and with pins done in the old single pin.h style...I was able
to get the display working fine save for needing to turn Delta Segments
per Second down. But that's a common graphics lcd issue being looked
into right now.
I need assistance in understanding how the new divided pins files fit
together because my previous attempts at trying to get it to work
appropriately didn't seem successful. This originally came from trying
to find out how to swap the XYZ Min and Max Endstop pins in the Azteeg
X3 Pro. It only comes with one set of connectors and they're Min
Endstops. My previous experience didn't turn out well trying to tell the
firmware to home to the Min Endstops so the best solution I found was to
swap the pins in the firmware. If I'm missing a conflict with a setup
other than delta please let me know, but it makes sense in my setup.
Here were a few changes that I had to make/add lines for the 4th hotend.
A compiling problem in the Temperature.cpp and missing lines in
configuration.h and configuration_adv.h. I added these lines in all of
the example configs too.
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
The previous calc was wrong. Between N points there are only N-1 gaps,
not N.
So changing AUTO_BED_LEVELING_GRID_POINTS to
(AUTO_BED_LEVELING_GRID_POINTS-1)
Due to the fix for #1248, X and Y probe offsets must not be floats.
The compiler does not support comparing float values: "error: floating constant in preprocessor expression"
The loss in X/Y precision shouldn't matter for Z probes, as most microswitches or inductive sensors are larger than 1mm square anyway.
Due to the fix for #1248, X and Y probe offsets must not be floats.
The compiler does not support comparing float values: "error: floating constant in preprocessor expression"
The loss in X/Y precision shouldn't matter for Z probes, as most microswitches or inductive sensors are larger than 1mm square anyway.
- Fixed issue when BAL area probing is shorter than it should be for
grid probing
- Warning when BAL activated with Delta Kinematics
- Fix XY_TRAVEL_SPEED when homing Z axis
Configuration.m: Set PID_INTEGRAL_DRIVE_MAX from PID_MAX from BANG_MAX.
Current defaults are all 255. If it makes sense to reduce them, they should come down together, and
be in a PID_INTEGRAL_DRIVE_MAX <= PID_MAX <- BANG_MAX relationship.
Changes to support displaying the real-time filament width and the
volume factor on a 20x4 LCD. The data is displayed on the 4th line.
First the status message is displayed for 5 seconds, and then the
filament data is displayed. The status message can be seen by
re-selecting the info screen in the menu.