REVERT THIS CHANGE
In proper use, we want to force the vendor to update this file to reflect distribution parameters
However, until most users have converted to automatic versioning,
we “grant them a pass”
Call kill() only once when triggered by a temperature error
to avoid stack overflow when called from interrupt.
Some clean up for calls of disable_all_heaters().
'disable_all_heaters()' is called in kill() and again when 'killed' is already set inside _temp_error().
Shift call of start_watching_heater() into setTargetHotend()
to warrant watching is set or reset.
Make setTargetBed() in _lcd_preheat() dependant of TEMP_SENSOR_BED.
Use disable_all_heaters() in lcd_cooldown() and abort_on_endstop_hit.
Use _temp_error() for all errors thrown by different mechanisms
Now ending in an endless loop.
Tidy up the output format.
We now get:
ERRORTEXT ", system stopped! Heater_ID: " HEATERID
Where ERRORTEXT can be:
"Heating failed"
"Thermal Runaway"
"MAXTEMP triggered"
"MINTEMP triggered"
and soon
"Thermal Jump"
HEATERID can be
0, 1, 2 ,3 , "bed"
This messages are always followed by the common:
"Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
- Use a global pointer for the current sanitized command
- Pre-sanitize the current command to bypass `N` and nullify `*`,
removing the need for handlers to bypass, ignore, or nullify these
parts, and reducing overhead for `code_seen`, etc.
- Pre-skip leading whitespace.
- Only look for G, M, T codes at the start of the command.
- Verify that G, M, T codes are followed by command codes.
Moved SDCARDDETECTINVERTED and SDSLOW to Conditionals.h.
Added U8GLIB_LM6059_AF to define display specific actions.
Added reminder to compile in u8glib